Vacuum Switch
With a single-pole double-throw contact, these vacuum switches enable ON and OFF point control signals to be simultaneously received at the maximum or minimum operating pressure, while keeping the change in operating pressure very small.
Additionally, the entire vacuum side is made of SUS-304, and the welded air seal allows connection to high vacuum. Thus, these vacuum switches can also be used as protection for automated vacuum equipment and as a switch for safety circuits.
Components
Features
- With a single-pole double-throw contact, ON and OFF point control signals can be simultaneously received at the maximum or minimum operating pressure.
- Additionally, the entire vacuum side is made of SUS-304, and the welded air seal allows connection to high vacuum.
- Has a long life of over 10,000 times, while keeping the change in operating pressure very small.
- V-015VS-T vacuum switch is a quick-release type with a φ15 gauge adapter.
Applications
Protection of automated vacuum equipment and as a switch for safety circuits. Retrieval of control signals for various vacuum systems.
Specifications
Model | V-070VS-I | V-015VS-T |
---|---|---|
Operating pressure (At black - yellow lead wire) |
OFF : Atmospheric pressure to Atmospheric pressure minus 5.4kPa | |
ON : Atmospheric pressure minus 7.0kPa to atmospheric pressure minus 18.7kPa |
||
Operating degree of vacuum | Atmospheric pressure* to Approx. 10-7Pa | |
Leak | 1.33x10-11Pa·m3/sec or less | |
Fluid | air, gas (excluding corrosive gases affecting SUS-304) | |
Allowable heating temperature |
40℃ | |
Operating environment temperature |
-10℃ to +40℃ | |
Material | Vacuum side all SUS-304 | |
Life | 10,000 times or more | |
Connection flange | φ70ICF | φ15 gauge adapter |
Electrical ratings | Rated voltage - Resistance load AC250V - 15A DC125V - 0.6A DC250V - 0.3A |
Ambient temperature : 20±2℃
Ambient humidity : 65±5%RH Operation frequency : 30 times/min |
Minimum applied load (Refernce value) : DC5V 160mA | ||
Weight | 500g | 260g |
* Please use the internal pressure with less than atmospheric pressure plus 50kpa(0.05MPa).
(Recommend less than atmospheric pressure plus 20kpa(0.02MPa))
When applying pressure to the inside of the vacuum switch V-015VS-T, take measures so as not to jump out of the φ15 adapter.
Dimensions
Parts Number
Parts Number | Model | Description | Remarks | Code |
---|---|---|---|---|
0160-18920 | V-070VS-I | Vacuum Switch | With φ70ICF | 29210 |
0160-18938 | V-015VS-T | Vacuum Switch | For φ15 gauge adapter | 29211 |